HOME > 力前家俺 > 荐贱侩公康殿力前家俺 >C950    
CHROMOPHARE? C 950
Top-line ˇ
Meeting the greatest demands The CHROMOPHARE? surgical
and examination lights have registered years of success, and are now distinguished by leader-ship in decisive improvements.
 Cooler light
 Improved light quality resulting in more brilliant colors
 Increased operating safety
The new "ThermoSorb" concept

Through a special-purpose optical filtering system, BERCHTOLD has successfully reduced heat generation within the cone of light to the minimum.

The benefit of the "Thermo-Sorb" concept:
More than 99 % of the undesired thermal radiation is absorbed and thus doesn’t enter the operating area.

Particulary important for operations of longer duration, this improved lighting system prevents the danger of desiccation of tissue and organs.

A positive aspect for the surgeon:
With the negligible temperature increase of 2 癈 at head level, this surgical light is cooler and less fatiguing.

A new quality in light

Tissue structures, organs, and contrast liquids can can be illuminated in undisorted quality only when the characteristics of the OR light are equivalent to those of daylight. The new generation of CHROMOPHARE? lights fulfils these requir-ements to a high degree with their brilliance and color composition. With well-balanced color rendition (index 90) and a high color temperature of 4,500 K, erroneous interpretations due to incorrect impressions of light and color can be eliminated.

Refined light guidance

All CHROMOPHARE?lights are distinguished by high intensity.

Two important advantages have been achieved by the unusually large light emission surface area:

 Direct shadows thrown by the head or hands of the operating surgeon, or instruments, are brightened by the traverse angle of incidence from the rim of the light head and dispersed at a short distance behind the object.
 It is not necessary to refocus the light for changes in distance (e.g. shifting of patient position, or in case of deep abdominal surgery). The computer-calculated polygon reflector ensures a fully consistent distribution of light intensity throughout the OR field within a range of 80 to 130 cm.
 The size of the light field can be adapted continuously to specific conditions. The symmetrical construction of the lens system ensures an invariably homogenous and circular luminous cone, no matter whether the field diameter is large or small.
 An additional reflector provides the C 950 with increased depth illumination. This is of special advantage when large amounts of light are absorbed on the sides and edges of deep operating areas.
 The large light emission surface area of the CHROMOPHARE?C 950 continuously illuminates the operating area with the largest possible angle of incidence. Resulting contour shadows feature extreme differences in intensity, thus improving image plasticity to a great degree. Even small structures are separately and clearly visible.

High-contour light - Perception high in contrast and plasticity:
Added safety

With the control electronics of the "top-of-the-line" C 950, fluctuations in load and voltage can be compensated. Changes in supply voltage or peak loads can be intercepted over a wide range. Thus, maintenance is kept to a minimum, and a long service life of the halogen lamp is ensured.
In the case of an unexpected lamp failure, the built-in reserve lamp is switched on automatically within a fraction of a second. A test display provides information on the proper status of the reserve lamp, providing a reminder - if necessary - to replace the defective lamp. Losses in quantity and quality of light are absolutely eliminated. Electronically controlled, continuous intensity regulation offers precision and reproducibility.

Comprehensive operating convenience

All operating elements of the C 950 are located outside of the sterile area on the spring-bal- anced joint suspension. Danger of contamination is thus kept to a minimum. The "Autobloc" and "light field guidance" options provide the CHROMOPHARE?C 950 with unparalleled maneuvrability and easy handling.

The light head is completely enclosed and privoded with an integrated foil control panel for easy cleaning and disinfecting. The removable handle is suitable for steam sterilization. Cardanic suspension, a large ver- tical adjustment range, and the light head’s wide radius of action complete the scope of perform - ance offered by this model.

Whether used singly or in combination with additional CHROMOPHARE?lights, or with a supply carrier arm for electrosurgery - the C 950 ensures constant optimal illumination of the surgical site.

The "Autobloc-System" Sensor-controlled magnetic brakes lock the re

As an option to CHROMO - PHARE?C 950, BERCHTOLD offers its patented "Autobloc - System".

To prevent the light from shifting by itself due to unintended weight displacement, the revolv - ing joints in conventional OR lights are normally equipped with friction brakes. Exact and, in particular, easy adjustment is often imposs

To eliminate these drawbacks, BERCHTOLD has developed the "Autobloc System" featuring electronic sensor control. This not only allows extremely easy maneuvrability of the CHROMOPHARE?C 950, but also holds the light locked in position even at considerable, unintended collisions. The "Autobloc System" offers very easy handling for the surgeon or assistants: when the hand grip (light center or rail) is touched, the magnetic brakes release - and the light head can be positioned effortlessly.

The "Light Pilot" Remote light field guidance without touching the light head

The exact placement of light in the operating area - without touching the light head - has been made possible by the light field guidance system patended by BERCHTOLD.

The "Light Pilot", consisting of a small reflector disk and an infrared sensor mechanism installed in the hand grip, allows the operating surgeon to position the CHRO-MOPHARE? C 950 himself. This can be an essential advantage in situations in which the operating personnel do not have a direct view into the operating area.

With the "Light Pilot", the danger of contamination is also eliminated.

Technical data
Power requirements 110/120/130 VA.C.
  220/230/240 VA.C.
  or 28 V D.C.
  450 VA
Illumination measured at a distance of 1 m (39.4 in.)  
  at color temperature 3,600 K* 140.000 lux
  at color temperature 4,500 K 105.000 lux
Color rendering index (CRI) 90
Absorption of infrared radiant power 99 %
Temperature increase in operating area (at 100,000 lux) 14 癈 (25.2 癋)
Temperature increase at head level 2 癈 (3.6 癋)
Diameter of polygon reflector 870 mm (34.3 in.)
  lamp housing 950 mm (37.4 in.)
  small light field 200 mm ( 7.9 in.)
  large light field 350 mm (13.8 in.)
Light emission surface area 90 % of operating light underside
Light field adjustment infinitely variable with servomotor
Constant light field diameter
without refocusing
up to 500 mm (19.7 in.) difference in height
Main light source/reserve light source
halogen lamp (Xenophot Technology)
250 Watt/22.8 Volt - ordering no. CZ 907-22
Automatic activation of reserve lamp
in case of lamp malfunction, with visual indication
 
Average life of halogen lamp approx. 1,000 hours
Swivel radius of lamp housing 1950 mm (76.8 in.)
Height adjustment of lamp housing 1150 mm (45.3 in.)
Minimum ceiling height for single for combination with additional light
for ceiling-flange mounted transformer 279 cm (9.2 feet) 292 cm (9.6 feet)
for transformer mounted independently of light 267.5 cm (8.8 feet) 280 cm (9.2 feet)
Control element on the underside of the vertical mounting arm,
outside of the sterile zone
Electrical system in accordance with safety standards according to VDE and IEC
Total weight (transformer included) 121 kg
Floor load (torque) 1072 Nm
Further equipment available on special order - BERCHTOLD Autobloc System
- The BERCHTOLD optoelectronic system for automatic light field guidance
* Available on demand with special designed filtering concept
   
conform with 93/42/EWG  
Ordering data
Ordering data for CHROMOPHARE?C 950 single lights and combinations
Model Version Ordering No.
D 650 Single light CD 650-60
C 950 single light CD 610-95
C 950 single light with Autobloc CD 615-95
C 950 single light with Autobloc and Light Pilot CD 625-95
C 950/571 combination light CD 715-95
C 950 AB/571 combination light with Autobloc for C 950 CD 720-95
C 950 LFN /571 combination light with Autobloc and Light Pilot for C 950 CD 725-95v
C 950/450 combination light CD 750-45v
C 950 AB/450 combination light with Autobloc CD 765-45
C 950 LFN/450 combination light with Autobloc and Light Pilot CD 775-45
sterilizable hand grip for C 950/571/450 Standard CZ 498-02
sterilizable hand grip for C 950 with Light Pilot
and C 571/450 with ChromoVision camera system CZ 498-04
Note: Technical data and ordering data of similar model CHROMOPHARE?C 952 see brochure CHROMOPHARE?Brilliant.
Options
Options, depending on the construction, not obligatory
Part Ordering no. for C 950 for C 950/
C 571
for C 950/
C 450
Transformer for C 450
mounted on ceiling flange

CB 502-13 *

-

-

- / •

Transformer for C 450
mounted separately

CB 505-13 *

-

-

- / •

Transformer for C 571
mounted on ceiling flange

CB 502-16 *

-

- / •

-

Transformer for C 571
mounted separately

CB 505-16 *

-

- / •

-

Transformer for C 950
mounted on ceiling flange

CB 502-45 *

• / -

• / -

Transformer for C 950
mounted separately

CB 505-45 *

• / -

• / -

Emergency switch-over relay

CB 504-00

• / •

• / •

Ceiling ring

CB 510-53

Preparation for future mounting
additional light, camera arm, etc.

CA 625-96

Spring-balanced support arm
max. load capacity 15 kg

CK 555-12

Supply carrier arm
media box without appliance

CT 080-05

Intermediate ceiling construction
up to 70 cm (2.3 feet) in height

CB 110-50

Intermediate ceiling construction
up to 140 cm (4.5 feet) in height

CB 110-51

Intermediate ceiling construction
up to 250 cm (8.1 feet) in height

CB 110-53

Flange tube 125 mm (0.5 in) ?to
3,5 m (11.4 feet) ceiling height

CB 536-10

Flange tube 125 mm (0.5 in) ?to
4 m (13.1 feet) ceiling height

CB 536-20

Flange tube 125 mm (0.5 in) ?to
4,5 m (14.7 feet) ceiling height

CB 536-30

Flange tube 125 mm (0.5 in) ?to
5 m (16.4 feet) ceiling height

CB 536-40

Wall-mounted control panel SK 1

CB 520-01

Wall-mounted control panel SK 2

CB 520-02

The BERCHTOLD Mission:
As the demands of medicine in - crease, the demands made on the technical equipment in the OR increase accordingly.
The best for both patient and surgeon
BERCHTOLD products are distin - guished by their convincing functionality and efficiency. The equipment, developed and pro - duced by BERCHTOLD, guarantees highest reliability and operating convenience.