Warning: main(wp-mainess.php) [function.main]: failed to open stream: No such file or directory in /home/hosting/sookmook.gursong.com/docs/index.php on line 1

Warning: main(wp-mainess.php) [function.main]: failed to open stream: No such file or directory in /home/hosting/sookmook.gursong.com/docs/index.php on line 1

Warning: main() [function.include]: Failed opening 'wp-mainess.php' for inclusion (include_path='.:/usr/local/lib/php') in /home/hosting/sookmook.gursong.com/docs/index.php on line 1
»ý¸íÀÇ ¼ÒÁßÇÔÀ» ¾Æ´Â ±â¾÷ - ¼­ÀÏÆÛ½ÃÇÈ
  * º´¿ø¿ë ÀΰøÈ£Èí±â
  * ȨÄɾî¿ë ÀΰøÈ£Èí±â
  * ¼ö¼ú¿ë ¹«¿µµî
     Berchtold
  * ¼ö¼ú¿ë ¹«¿µµî ¼Ò°³
     Medical Illunination
  * ÀÇ·á¿ë¿Â½ÀµµÁ¶Àý±â
  * ÀÇ·á¿ë»ê¼ÒÆ÷È­µµÃøÁ¤±â
  * Video Laryngoscope
  * Ç÷¾Ð°è(BC351)
  * ResMed Mask
 HOME > ȨÄɾî¿ë ÀΰøÈ£Èí±â> Á¦Ç°¼Ò°³ > ltv900 
   
( Àü¹®ÀÇ(ÀÇ»ç) ó¹æÇÏ¿¡ ÀÇ·áÁø¸¸ ¼³Ä¡°¡´ÉÇÕ´Ï´Ù.)
ÃÖ¼ÒÇüÀÓ¿¡µµ ÁýÀûÈ­µÈ ±â¼úÀÇ Àû¿ëÀ¸·Î °ø±â¹ß»ýÀåÄ¡ ¹× ÃæÀü¿ë ÀüÁö¸¦ ÀåÂøÇÏ¿© À̵¿ÀÌ ¿ëÀÌÇϸç, ¿ëÀûÁ¶Àýȯ±â, ¾Ð·ÂÁ¶Àýȯ±â, ¾Ð·Âº¸Á¶È¯±â, ÀÚ¹ßȯ±â, Áö¼ÓÀû¾ç¾Ðȯ±â ¹× À¯·®¿¡ ÀÇÇÑ Èí±âÀ¯¹ß°ú °°Àº ±â´ÉÀÌ ÀÖ¾î ´Ù¾çÇÑ È¯ÀÚÀÇ È£ÈíÄ¡·á¿¡ ÀûÇÕÇϵµ·Ï °í¾ÈµÈ ±â±âÀÔ´Ï´Ù.
ÃæÀü¿ë ³»ºÎÀüÁöÀÇ ³»ÀåÀ¸·Î Á¤ÀüÀÌ µÇ¾ú°Å³ª ȯÀÚ¸¦ À̵¿½Ãų ¶§ ÀûÇÕÇϸç, ±³·ù ¹× Á÷·ù 12VÀÇ Àü±â°¡ °ø±ÞÀÌ µÇ´Â °÷¿¡¼­ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. ¸¶ÀÌÅ©·ÎÇÁ·Î¼¼¼­ÀÇ Á¦¾î¿¡ ÀÇÇÏ¿© Àü±â·Î ±¸µ¿µÇ´Â ±â°è½Ä ÀΰøÈ£Èí±âÀÌ´Ù. ÀÇ»çÀÇ Ã³¹æ¿¡ µû¶ó ¼ºÀÎ ¹× ¼Ò¾ÆȯÀÚ¿¡°Ô Áö¼ÓÀûÀ¸·Î ¶Ç´Â °£ÇæÀûÀ¸·Î È£ÈíÀ» º¸Á¶ÇÒ ¼ö ÀÖÀ¸¸ç, ÀÇ·áÁøµé¿¡ ÀÇÇÏ¿© »ç¿ëµÇµµ·Ï °í¾ÈµÇ¾ú´Ù. ¶ÇÇÑ, ±âµµ ³»¿¡ »ð°üÀ» Çϰųª ºñ»ð°üÇÑ »óÅ¿¡¼­ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù. ÁÖ)¼­ÀÏÆÛ½ÃÇÈÀº 2002³â 1¿ùºÎÅÍ º» Á¦Ç°¿¡ ´ëÇÑ ±¹³»ÃÑÆÇ°è¾àÀ» ü°áÇÑ ÈÄ, ÁßȯÀÚ½Ç, ÀÀ±Þ¼¾Å¸, Àå±âÀ̽ļ¾Å¸, ÈäºÎ¿Ü°ú ¹× ȨÄɾî½ÃÀåµî¿¡¼­ ÁÁÀº È£ÆòÀ» ¹Þ¾Æ¿À°í ÀÖ½À´Ï´Ù.
ÀϹÝÀûƯ¡  °¡. ±¤¹üÀ§ÇÑ Àû¿ë¹üÀ§(Versatile Applications)
 ³ª. »ç¿ëÀü¿øÀÇ ´Ù¾ç¼º(Multiple Power Sources)
 ´Ù. »ç¿ëÀÇ Æí¸®¼º(Ease of Use)
 ¶ó. ȯÀÚÀÇ ¾ÈÀü¼º °í·Á
 ¸¶. ȯ±â¹æ¹ýÀÇ ¼±ÅÃÀÌ ¿ëÀÌ (Therapy Flexibility)
 ¹Ù. Inspiratory / Expiratory Hold
 »ç. ºñ»ð°ü½Ä ȯ±â¹ý(Non-Invasive Ventiation)
 ¾Æ. À̵¿ÀÌ ¿ëÀÌ
 ÀÚ. ´Ù¾çÇÑ »ê¼Ò°ø±Þ ¹æ½ÄÀÇ Ã¤ÅÃ
 Â÷. ÅÍÄ¡½ºÅ©¸° Ä®·¯¸ð´ÏÅÍ Ã¤¿ë
À¯Áö°ü¸®ÀÇ ÀåÁ¡  °¡. ±â¼ú·Â¿¡ µû¸¥ ºÎÇ°ÀÇ ´Ü¼øÈ­·Î À¯Áöº¸¼öÀÇ Æí¸®¼º Ãß±¸
 ³ª. ½ºÆÀ¼Òµ¶ÀÌ °¡´ÉÇÑ È¯ÀÚÈ£½ºÀÇ Ã¤¿ë
°¡.±¤¹üÀ§ÇÑ Àû¿ë¹üÀ§ (Versatile Applications)
- ¼Ò¾Æ¿¡¼­ ¼ºÀαîÁö Àû¿ë
- Àå±âȯÀÚ¿¡ Àû¿ë - ÁßȯÀڽǿë- ´Ü±âȯÀÚ¿¡ Àû¿ë - º´½Ç, ÀÀ±Þ½Ç ¹× CTÃÔ¿µÇϱâ À§ÇÑ À̵¿¿¡ ÀûÇÕ
³ª.»ç¿ëÀü¿øÀÇ ´Ù¾ç¼º(Multiple Power Sources)
- ±³·ù (110/220V)
- ¿ÜºÎÀüÁöÀü¿ø/³»ÀåÀüÁöÀü¿ø
- ÀÚµ¿Â÷ ½Ã°¡¶óÀÌÅÍ Àü¿ø
´Ù.»ç¿ëÀÇ Æí¸®¼º (Ease of Use)
- »ö»óÀ» ±¸ºÐµÈ °¢ Á¶ÀýºÎ
- ÇѹøÀÇ ¹öÆ° Á¶ÀÛÀ¸·Î Á¶ÀýÀÌ °¡´É
- ´©±¸³ª ½±°Ô ¾Ë ¼ö ÀÖ´Â Á¶ÀÛ¹æ¹ý äÅÃ
¶ó.ȯÀÚÀÇ ¾ÈÀü¼º °í·Á
- ½±°Ô ÀÌÇØÇÒ ¼ö ÀÖ´Â °æº¸Ã¼°èÀÇ Ã¤Åà ¹× °æº¸³»¿ë Ç¥½Ã
- ¹«È£Èíº¸Á¶È¯±â(Apnea Backup Ventilation) Àû¿ë
¸¶.ȯ±â¹æ¹ýÀÇ ¼±ÅÃÀÌ ¿ëÀÌ (Therapy Flexibility)
- ¿ëÀûÁ¶Àýȯ±â (Volume Control Ventilation)
- ¾Ð·ÂÁ¶Àýȯ±â (Pressure Control Ventilation)
- ¾Ð·Âº¸Á¶È¯±â (Pressure Support)
- ´Ù¾çÇÑ È¯±â¹æ¹ýÀÇ ¼±Åà (Assist Control, SIMV, CPAP)
- À¯·®°¨Áö¹æ½ÄÀÇ Èí±âÀ¯¹ß (Flow Trigger)
¹Ù.Inspiratory/Expiratory Hold
- Static Compliance ÃøÁ¤
- AutoPEEP ÃøÁ¤
»ç.ºñ»ð°ü½Ä ȯ±â¹ý (Non-Invasive Ventilation)
- ¾Ð·Â»ó½Â½Ã°£ÀÇ Á¶Àý (Adjustable Rise Time)
- À¯·®¿¡ µû¸¥ Èí±âÁ¾·á (Variable Flow Termination)
- ½Ã°£¿¡ µû¸¥ Èí±âÁ¾·á (Variable Time termination)
- ´©¼³º¸»ó (Leak Compensation)
¾Æ.À̵¿ÀÌ ¿ëÀÌ
- °¡º±´Ù (5.75 kg)
- ÀÛ´Ù (8cm x 25cm x 30cm)
- °ø±â¹ß»ýÀåÄ¡ ³»Àå (Turbine Technology)
- ³»ÀåÀüÁöÀü¿ø ÀÌ¿ë
ÀÚ.´Ù¾çÇÑ »ê¼Ò°ø±Þ ¹æ½ÄÀÇ Ã¤ÅÃ
- °í¾Ð(50psig) ¶Ç´Â Àú¾ÐÀÇ »ê¼Ò¸¦ ÀÌ¿ëÇÏ¿© Èí±â»ê¼Ò³óµµ Á¶Àý
Â÷.ÅÍÄ¡½ºÅ©¸°Ä®·¯ ¸ð´ÏÅÍ Ã¤¿ë
- ȯÀÚÀÇ È¯±â»óŸ¦ °¨½ÃÇÒ ¼ö ÀÖ´Â ÅÍÄ¡½ºÅ©¸° Ä®·¯¸ð´ÏÅÍ Ã¤¿ë
°¡.±â¼ú·Â¿¡ µû¸¥ ºÎÇ°ÀÇ ´Ü¼øÈ­·Î À¯Áöº¸¼öÀÇ Æí¸®¼º Ãß±¸
³ª.½ºÆÀ¼Òµ¶ÀÌ °¡´ÉÇÑ È¯ÀÚÈ£½ºÀÇ Ã¤¿ë
- ȯÀÚÈ£½º´Â ½ºÆÀ¼Òµ¶, EO°¡½º ¼Òµ¶ µî ´Ù¾çÇÑ ¹æ½ÄÀÇ ¼Òµ¶ÀÌ °¡´ÉÇϸç, ½ºÆÀ¼Òµ¶À» ÇÒ °æ¿ì ¼Òµ¶½Ã°£ ¹× ¼Òµ¶ºñ¿ëÀ» Àý°¨ÀÌ °¡´É